Line Set Replacement on an R-454B Install, With a Job Site Check-In

A new R-454B refrigerant system shouldn't run on line set sized for an old R-22 unit. On this install the undersized liquid line came out and a new 3/8 inch line went in before charging.

What R-454B means for your AC or heat pump, and why your R-410A system can stay: our full guide.

5.0 stars across 1,132 reviews

Get your price in writing

Send this and the office calls or texts you back to set a time.

This field is for validation purposes and should be left unchanged.

We’ll call or text this number about your request. By sending it you agree to our terms and privacy policy.

Rather talk now? (703) 997-9757

Licensed and insuredVirginia Class A contractor #2705192276

24/7 emergency serviceOften same-day, and we will tell you honestly when we can get there.

Our own HVAC installersA dedicated heating and cooling team, separate from our plumbers

Price in writing firstYou see every option priced before anything is ordered

What you’re seeing in this video

Behind a house, Tyler Griffin, SwiftPro's owner, checks in by face cam with a young installer in a black SwiftPro polo. The tech is at the outdoor condenser with digital manifold gauges connected, charging the system and pointing out the line set.

He explains that the old line was 1/4 inch, sized for an R-22 unit and badly undersized for the new R-454B system, so they ran a new 3/8 inch line. The disconnect and the electrical whip, the flexible conduit feeding the unit, are new too. He plans to let the system settle before adjusting the charge.

Job footageSwiftPro
Topic
HVAC Installation Craft
Length
1:23
Posted
September 2, 2026
Shot by
The SwiftPro crew, Northern Virginia
What they say on camera

All right, walking around the backside of the house here to go check out Elijah. What's going on with Elijah? We are just charging up the unit to because this is a pretty long line set. We actually just installed the 3/8 line set today.

What was the previous size? 1/4. 1/4 and that was undersized, correct? Incredibly so.

Yeah, that's for a R22 unit. We have the R454B. You put a new disconnect on here, too? New disconnect here.

Okay. The feed Everything when we replace units, we don't reuse any of this stuff. We don't want any carryover that could cause a problem. So, everything from the disconnect out to the unit is all new.

The whip there, electrical line that's running there. So, how much longer is it going to take you to get this charging completed? Well, I'm going to make sure in about 20 minutes before I change anything in the system. So, 20 minutes, probably.

Anything that you enjoy about HVAC in particular? It makes you think. And I like taking something that doesn't work right and getting a new one and making it work. Love that.

All right. If you guys need a HVAC system installed at your place, have our team do it and you can request Elijah and Oscar. They are an awesome install team and they love serving and they love making sure that the system is installed correctly and will last for for many, many years to come.

Why it matters in your house

  • R-454B is the refrigerant replacing R-410A in new systems, and R-22 is long phased out. If your current system is old enough to run R-22, plan on a full line set check at replacement.
  • Reusing the old line set can be fine if it's the right size, clean and leak free. If it isn't, a new one is far easier to live with than a compressor failure down the road.
  • Long line sets need extra refrigerant beyond the factory charge. A tech who charges by gauge readings and measured weight gets it right instead of guessing.

Do you have to replace the line set with a new R-454B system?

Not always. A line set can be reused if it's the correct size for the new equipment, in good shape, and cleaned and tested properly. Lines left from an old R-22 system are often undersized or contaminated with old oil, and that's when replacement is the safer call, like on this job.

Want it done at your place? See HVAC Installation Craft at SwiftPro or call (703) 997-9757.

Want this done at your house?

Rather pick the day yourself? Book online.

SwiftPro Heating, Cooling & Plumbing
4230 Lafayette Center Dr N, Chantilly, VA 20151
44679 Endicott Dr, Suite 211, Ashburn, VA 20147
Virginia Class A contractor license #2705192276

Call Now Book Online
5.01,132 reviews