Video · Heat Pumps and Heat Strips

Heat Pump Air Handler Swap in an Attic Near 100 Degrees

A heat pump air handler in the attic needs a drain pan and a float safety switch, or a clogged drain can soak the ceiling below. On this attic replacement, both went in new.

5.0 stars across 1,132 reviews

Get your price in writing

Send this and the office calls or texts you back to set a time.

This field is for validation purposes and should be left unchanged.

We’ll call or text this number about your request. By sending it you agree to our terms and privacy policy.

Rather talk now? (703) 997-9757

Licensed and insuredVirginia Class A contractor #2705192276

24/7 emergency serviceOften same-day, and we will tell you honestly when we can get there.

Our own HVAC installersA dedicated heating and cooling team, separate from our plumbers

Price in writing firstYou see every option priced before anything is ordered

What you’re seeing in this video

Tyler Griffin, SwiftPro's owner, climbs into an attic to check on the install, appearing by face cam over the work. It's close to 100 degrees up there, a jobsite fan running, the return plenum cut open where the new air handler connects.

The installer is wiring the new heat pump air handler. He's set a new drain pan under it and added a float safety that shuts the system off if water backs up into the pan. He also ran a new 3/8 inch line set out to the heat pump.

Outside, the wrapped SwiftPro vans sit at the curb of a gray colonial.

Job footageSwiftPro
Topic
Heat Pumps and Heat Strips
Length
1:31
Posted
September 1, 2026
Shot by
The SwiftPro crew, Northern Virginia
What they say on camera

Checking on my man Oscar over here. It is hot. You know what the temperature is up here right now? Maybe a hundred.

Feels hotter than that. Feels like maybe a hundred and ten. It does have a ridge vents up there, but not a lot of air movement going on. So, we got a heat pump air handler combination going on here.

You're working on the wiring right now? Yes. Put a new pan in, right? Yeah, new pan, new easy trap.

Nice. Looks good. Any challenges on this install? New 3/8 line set.

Okay, so you had to run a new 3/8 line set from the indoor coil, or the air handler rather, to the outdoor heat pump. Want to explain what that easy trap is for, Oscar? That's the safety for the condenser. So, it's a water safety, right?

safety. Yep. So, that will shut off the unit if it leaks too much, right? Sometimes the the drain was closed.

So, the pan is there to prevent water from leaking right into the house. And then, if it's leaking water into the pan though, you still want to shut it off so it can't overflow. That way it would shut the unit off and stop the water from coming back from the condensate line. So, that is the purpose.

And very important, a lot of houses we find don't have these water safeties, then all of a sudden you have a whole bunch of ceiling damage or wet insulation. That can be a disaster. It causes thousands or tens of thousands of damage real fast. Something very, very important.

These guys work hard and often hot conditions in the summertime, so we appreciate what they do. He's got a little Milwaukee fan blowing on him. He's working hard and just wrapping up the install.

Why it matters in your house

  • Attic air handlers sit right over your ceiling. If the condensate drain clogs and there's no pan or float switch, the water ends up in the drywall and insulation.
  • Lots of older attic installs never got a float safety. If yours is missing one, adding it is a small job that prevents a very big repair.
  • Attic work in summer is brutal. Booking a heat pump and air handler replacement before peak heat is easier on the installers and on your schedule.

Does an attic air handler need a drain pan?

Yes. Building code calls for a secondary pan under attic equipment that makes condensate, and most installers pair it with a float switch. If the main drain clogs, the switch shuts the system off before the pan overflows. Without it, you find out when water stains show up on the ceiling below.

Want it done at your place? See Heat Pumps and Heat Strips at SwiftPro or call (703) 997-9757.